KeinInternet

Home › Emergency guides › Shelter in the basement — conversion & protective ventilation

Shelter in the basement — conversion & protective ventilation

Honestly, up front: a converted home basement is not a bunker. It protects well against fragments, debris, blast waves at some distance, radioactive fallout and cold — not against a direct hit. The steps are sorted by effect per effort.

1. Choose the room (free)

2. Secure the openings (biggest effect)

3. Ceiling & structure — only with professionals

Propping up the ceiling with building props and cross beams against falling debris is possible — ask a structural engineer first, do not alter load-bearing walls. In Switzerland, shelter construction is standard: Swiss shelter companies also advise on retrofitting.

4. Protective ventilation — air is the often forgotten problem

In a sealed room, people and animals use up the oxygen within hours, and CO₂ rises. Protective ventilation should do three things:

  1. supply filtered fresh air,
  2. create a slight overpressure in the room so that no unfiltered air gets in through gaps,
  3. keep running without mains power (hand crank or battery).

The most important rule

Never build the NBC/CBRN filter yourself. Home-mixed activated carbon, vacuum-cleaner, car or household filters do not protect reliably. What you can build yourself is the airtight ventilation line with overpressure around a purchased, certified NBC/CBRN shelter filter.

Layout (order of the airflow)

Outside air → weather protection/insect screen → blast valve → pre-filter (coarse filter) → certified NBC filter → radial fan (power + hand crank) → check valve → shelter (overpressure) → overpressure/blast valve on the opposite side → outside. In normal times fresh air runs through a bypass around the gas filter; only in an emergency do you switch over to filter mode.

Shelter ventilation in a home basement — diagram (improved) Filtered supply air → slight overpressure in the room → exhaust on the OPPOSITE side. OUTSIDE ① Air intake weather-protected, insect screen, not near the ground, away from exhaust ② BV Blast valve ③ Pre-filter replaceable ④ NBC filter CERTIFIED HEPA + act. carbon never DIY ⑤ Fan Radial, 12/24 V + hand crank ⑥ Check valve Bypass = fresh air in normal times (spares the gas filter) In an emergency switch over: air ONLY through ④ NBC filter Pipes: metal/pressure-resistant, airtight wall duct (collar + EPDM), filter housing completely airtight — no air may bypass the filter. Shelter slight overpressure (valve ⑦ opens at approx. 60 Pa) CO₂ meter < 2,000 ppm CO alarm Pressure gauge (Pa) all people + animals beds, water, radio, light, toilet, tools no combustion! (stoves, candles, generator) ⑦ OPV/BV ⑦ Exhaust to the outside opposite the intake, NEVER back to the intake Emerg. exit Light well: ~50 cm sandbags solid door, opens outwards · prop the ceiling only with a structural engineer Sizing (example: 4 shelter places) Filtered air: 3–10 m³/h per person → minimum 12 · good 24 · comfortable 40 m³/h → system for 25–40 m³/h (after the filter!) Battery: 40 W × 24 h ≈ 1 kWh → 1.2–1.5 kWh/day Your values: shelter shopping list Order of the airflow ① Intake → ② blast valve → ③ pre-filter → ④ certified NBC filter → ⑤ fan (power + crank) → ⑥ check valve → shelter (overpressure) → ⑦ overpressure/blast valve → outside Normal: bypass · emergency: NBC filter only Never ✗ DIY NBC filter / household filters ✗ underpressure (sucks air in through gaps) ✗ exhaust next to the intake ✗ opening filters or storing them damp ✗ combustion in the room (CO!) Installation/inspection: specialist + engineer

Our own, improved drawing. Corrected compared with the original: exhaust on the opposite side (not back to the intake), blast valve added at the intake, fresh-air bypass for normal times, sizing for your household. Original infographic: blog.hennweb.de (link below).

What happens in the NBC filter

Layer Works against
Pre-filter coarse dust, protects the expensive layers
High-efficiency particulate filter (HEPA) radioactive dust, bacteria/spores, aerosols
Activated carbon (often impregnated) chemical gases and vapours
After-filter carbon dust

How much air do you need?

Rule of thumb: 3 to 10 m³ of filtered air per person per hour — measured after the filter, not the fan's output without a filter.

Example: 4 shelter places
Minimum 12 m³/h
good 24 m³/h
comfortable (longer stay) 40 m³/h

→ In the example: a system for 25–40 m³/h of filtered air. Your exact values (shelter places, air volume, quantities) are calculated by the shelter shopping list from the household entered in the supplies calculator — large dog ≈ ½ place, small dog ≈ ¼ place.

Battery for the fan

Fan power (watts) × hours = watt-hours. Example: 40 W × 24 h = 960 Wh — with losses, plan 1.2–1.5 kWh of battery per day. Plus a hand crank as a reserve.

Installation notes

Materials list

Simpler alternative: a ready-made shelter ventilation unit with manual and electric operation (Swiss standard, tested). More expensive, but safer than a DIY build.

🛒 Shopping list with all parts, guide prices and links: EINKAUF-SCHUTZRAUM.html (also in the sidebar).

Final inspection: have the design and installation checked by a ventilation installer, shelter equipment supplier or building-services engineer.

5. Equipment for 2–14 days

With radioactive fallout the 7/10 rule applies: after 7 hours about 10 % of the radiation remains, after 49 hours about 1 %. The first 1–2 days are the most important.

6. Practise

7. Public shelters & old bunkers

Germany (as of 09/2026): Germany abandoned public shelter construction in 2007. Nationwide, 579 facilities with around 478,000 places are still designated (less than 1 % of the population) — according to the Federal Office of Civil Protection (BBK), none of them is operational. The federal government is not building new bunkers (Dobrindt, 14 Sept 2026); instead it has municipalities register underground car parks, tunnels and basements of public buildings as "protective locations" by the end of 2026. These are to be shown later in the NINA app. There is no date yet.

Switzerland: shelter construction is standard there. Shelters are allocated to the residents of the respective municipality — not to residents of neighbouring countries. You can find out your allocated shelter place from your municipality.

Other countries: information is provided by your country's civil-protection authority (see region box).

Beware of maps and ruins: objects marked as bunkers in OpenStreetMap are often old military bunkers or fortifications — usually locked ("access: no/private"), not shelters for civilians. Castle and fortress ruins are not shelters either. The many "assembly points" of companies and schools are fire assembly points, no protection during an air-raid alert.

What this means for you:

  1. Your basement remains protective location no. 1: reachable in under 2 minutes, with everyone in the household, including older people and animals. No public bunker beats that when warning times are short.
  2. When out and about during an air-raid alert: go to the nearest underground car park (lowest level, away from entrances), a basement or a solid building — not into the car.
  3. Ask once: at your town/municipality (public order office/civil protection) whether and where protective locations or public shelters have been registered. Then note them here: ……
  4. Keep your country's warning app up to date (Germany: NINA — the protective locations will appear there once the federal government releases them).

Sources (Germany): BBK protective structures; Münster Aktuell 14 Sept 2026 (Dobrindt, BMI municipal conference); Correctiv 13 May 2026; civil-defence facility directory geschichtsspuren.de (as of 2007).

Order by cost

Step Effort
Choose the room, tidy up, remove hazards low
Water, light, radio, toilet, beds, CO₂/CO alarms low–medium
Light wells with sandbags/boards, emergency exit medium
Solid door, ceiling props (structural engineer) medium–high
Protective ventilation with certified NBC filter high

Source for protective ventilation (section 4): summary and conversion based on "Schutzraum Filter selber bauen DIY", HennWeb blog (blog.hennweb.de/schutzraum-filter-selber-bauen-diy), as of July 2026 (German) — original with diagrams there. Rules of conduct for gases: BBK (Germany).

Get this and 30 more guides offline – even when power and internet fail.

Download for freeSupplies calculator